此页面上的内容需要较新版本的 Adobe Flash Player。

获取 Adobe Flash Player

热系统 -美国Process Technology-高纯度产品


潜入式电加热器

铁氟龙化学液槽加热器输出功率可达6,000 w。主要有两种类型:第一,TFB/TFW系列。结构小巧紧凑,其专利气排系统不仅提供了独特的安全性能,而且极大的延长了加热元件的使用寿命。第二,HX系列。全接地设计,构造极其坚固。备有适用于各种潜入式加热器的控制系统。

TF产品系列,潜入式加热器


该系列结构紧凑,N2气排功能 (专利权)极大地延长了该加热器的使用寿命。
The TF Series fluoropolymer immersion heaters are designed for the most demanding chemical applications and to provide years of trouble-free performance. The heaters are ideal for the Semiconductor, FPD, MEMS, and Biomedical industries, as well as other similar demanding applications.

A complete heater and control system package should include all of the following components:

• Immersion heater
• Temperature control with safety interlocks
• Power module
• Gas purge flow regulator module

 

 HX产品系列,潜入式加热器
 

该系列不仅具有安全的接地保护,而且其坚固的构造保障了超长的使用寿命。
Product Features and Benefits:
.5 to 27 kW, 10 watts/square inch nominal (1.5 watts/square centimeter).
120, 240, 480 volts standard, 208, 380, 415 and other voltages available.
Compatible with most plating tank solutions, inert to acids, anodizing and pickling solutions up to 212 degrees Fahrenheit (100 degrees Celsius) temperature.
Replaces quartz, alumina or graphite heaters.
Flat, spiral and L-shaped configurations available to meet your application.
Low watt density for even heating and long service life.
Non-contaminating, fluoropolymer sheathed stainless steel element.
Thermal protection standard (replaceable P1 or resettable P2/P8).
Grounded internal metal element for safety.
U.L. listed, CSA certified, CE compliant.
Lightweight, non-floating construction.
Vapor tight polypropylene terminal enclosure.
Standard 3 foot (1 meter) flexible PVC liquid tight conduit, other lengths available.
Polypropylene guards standard (optional fluoropolymer guards recommended for chromic acid or solutions exceeding 180 degrees Fahrenheit/82 degrees Celsius).
Single or three phase models available.
Custom lengths available. Consult factory.
Flexible leads standard.
Heavy wall fluoropolymer sheath reduces permeation and eliminates the need for gas purge systems.